Omron Healthcare ZFX-C Computer Monitor User Manual


 
Optical Graph
Meaning of Optical Graph
Precautions
Maximum outer diameter: 30 mm dia.
Camera Only ZFX-S/SC
CCTV Lenses
Model
Appearance
Focal length
Brightness
Filter size
3Z4S-LE
ML-0614
6 mm
F1.4
M27
P0.5
3Z4S-LE
ML-0813
8 mm
F1.3
M25.5
P0.5
3Z4S-LE
ML-1214
12 mm
F1.4
M27
P0.5
3Z4S-LE
ML-1614
16 mm
F1.4
M27
P0.5
CCTV Lens
3Z4S-LE
ML-3519
35 mm
F1.9
M27
P0.5
3Z4S-LE
ML-5018
50 mm
F1.8
M30.5
P0.5
3Z4S-LE
ML-7527
75 mm
F2.7
M30.5
P0.5
3Z4S-LE
ML-10035
100 mm
F3.5
M30.5
P0.5
Extension Tubes
Model Contents
3Z4S-LE ML-EXR
24.5
30 dia.
30 34.5
34.5 24.5
29
37 42.5 43.9
Set of 7 tubes
If using the ZFX-S/SC Camera (Camera only), refer to the optical graph below and select the lens and Extension
Tubes. The lens to be selected will depend on the size of the measurement object and the camera distance.
The X axis of the graph shows
the field of vision L (mm), and
the Y axis shows the camera
distance A (mm).
Camera
Extension Tube
thickness:
t (mm)
Camera
distance
A (mm)
Field of vision (mm)
Lens
30 dia.
30 dia.
30 dia.
30 dia.
30 dia.
32 dia.
32 dia.
32 dia.
Do not use the 0.5-mm, 1.0-mm, and 2.0-mm Extension Tubes attached to each other. Since these Extension Tubes are placed over the threaded section
of the Lens or other Extension Tube, the connection may loosen when more than one 0.5-mm, 1.0-mm or 2.0-mm Extension Tube are used together.
Reinforcement may be required for combinations of Extension Tubes exceeding 30 mm if the Camera is subject to vibration.
3Z4S-LE
ML-2514
25 mm
F1.4
M27
P0.5
The value "t0" indicates
applications where an
Extension Tube is not
needed and the value "t5"
indicates applications
where a 5-mm Extension
Tube is used.
40
100
1000
10000
4 10 100 1000
ML-0614
ML-0813
ML-1214
ML-1614
ML-2514
ML-3519
ML-5018
t0
t0.5
t1
t0
t0.5
t1
t1.5
t0
t0.5
t1
t1.5
t2
t0
t0.5
t5
t1.5
t2
t15
t10
t0
t0.5
t1
t1.5
t1.5
t2
t5
t10
t20
t0
t0.5
t1
t2
t5
t10
t15
t20
t25
t1.5
t2
t10
t15
t20
t25
t30
t35
t40
t1
t5
t0
200
1000
10000
2 10 100 1000
ML-7527
ML-10035
t2
t5
t10
t15
t20
t30
t35
t50
t45
t5
t10
t15
t20
t25
t30
t40
t35
t45
t50
t60
t0
t2
t40
t25
t0
3Z4S-LE
3Z4S-LE
Camera distance A (mm)
Camera distance A (mm)
Field of vision L (mm)
Field of vision L (mm)
t: Extension
Tube length
CCTV LensesSpecifications
Cameras
Item
Detection range (H x V)
Setting distance (L)
Image capture element
Effective number of pixels
659(H) x 494 (V)
Pixel size
7.4 µm (H) x 7.4 µm (V)
Shutter speed
Image rate function
Lens mount
Connection method
Material
Weight
Accessories
Lighting method
Pulse lighting
Red LED
Available
(center, measurement region) Not available
Not available Not available
15 VDC
Approx. 200 mA
Approx. 350 mA (15 VDC: approx. 150 mA,
48 VDC: approx. 200 mA)
(including current consumption when
optional lighting is connected)
Operating: 0 to + 40˚C, Storage: -20 to +65˚C (with no icing or condensation)
Operating: 0 to + 50˚C,
Storage: -20 to +65˚C
(with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
No corrosive gases allowed
1000 VAC 50 Hz/60 Hz 1 min
10 to 150 Hz Single-amplitude 0.35 mm 10 times for 8 min each in X, Y, and Z directions
150 m/s
2
3 times each in 6 directions (up/down, left/right, forward/backward)
Cable built-in type (cable length: 2 m)
Case: ABS, mounting fixture: PBT
Approx. 200 g (including mounting fixture and cable)
mounting fixture (ZFV-XMF) 1 p'ce,
Ferrite core 2 p'ce,
Instruction Sheet
mounting fixture
(ZFV-XMF2) 1 p'ce,
Ferrite core 2 p'ces,
Warning label 1,
Instruction Sheet
Ferrite core 2 p'ces,
Instruction Sheet
mounting fixture
(ZFV-XMF2) 1 p'ce,
Ferrite core 2 p'ces,
Warning label 1,
Instruction Sheet
mounting fixture
(ZFV-XMF) 1 p'ce,
Ferrite core 2 p'ces,
Instruction Sheet
Approx. 600 g
(including
mounting fixture
and cable)
Approx. 80 g
Instruction Sheet
Approx. 270 g
(including
mounting fixture
and cable)
Approx. 300 g
(including
mounting fixture
and cable)
Case: Aluminum die-cast,
Cover: Zinc-plated copper plate 0.5 mm thick,
Camera mounting base:ABS
Connector connection type
(camera cable ZFX-VS/VSR required)
IP65 (IEC60529)
ZFX-SC___: IP65 (IEC60529), ZFX-SC___W: IP67 (IEC60529)
IP20 (IEC60529)
500VAC 50 Hz/60Hz 1 min
Approx. 100 mA
15 VDC, 48 VDC 15 VDC, 48 VDC
Available (ZFV-LT Series)
Class 1 Class 2 Class 2 Class 1
Available
External lighting: 3Z4S-LT Series
Flash Controller: made by Moritex
Corporation 3Z4S-LT MLEK-C100E1TSX
Direct lighting
White LED
LED
Ty pe
Guide light
Optional
lighting I/F
Indicator Class*1
Current
consumption
Ambient
temperature range
Ambient humidity range
Ambient atmosphere
Degree of protection
Dielectric strength
Vibration resistance
(durability)
Shock resistance
(destructive)
Power supply voltage
(supplied from Controller)
Frame rate
(at capture of entire screen)
Partial function
(partial capture)
OFF Not available
Fine, Normal, High speed
Fine, Normal,
High speed
Not available Not available
1/2 partial, 1/4 partial
1/2 partial,
1/4 partial
C mount
1/170s to 1/20000s
Relationship between
setting distance and
detection range
ZFX-SR10 ZFX-SR50 ZFX-SC10
ZFX-SC50
/SC50W
ZFX-SC90
/SC90W
ZFX-SC150
/SC150W
ZFX-S
(monochrome type)
ZFX-SC
(color type)
5 mm x 4.9 mm to
9 mm x 8.9 mm
(variable)
10 mm x 9.8 mm
to 50 mm x 49 mm
(variable)
5 mm x 4.9 mm
to 9 mmx 8.9 mm
(variable)
10 mm x 9.8 mm
to 50 mm x 49 mm
(variable)
50 mm x 49 mm
to 90 mm x 89 mm
(variable)
90 mm x 89 mm
to 150 mm x 148 mm
(variable)
34 mm to 49 mm
38 mm to 194 mm 34 mm to 49 mm
31 mm to 187 mm 67 mm to 142 mm 115 mm to 227 mm
All-pixel capture inter-line
transfer type
1/3" CCD (monochrome)
All-pixel capture
inter-line transfer type
1/3" CCD (monochrome)
All-pixel capture
inter-line transfer type
1/3" CCD (color)
The CCTV lens is selected
according to the detection range
and the setting distance.
All-pixel capture inter-line transfer type 1/3" CCD (color)
96 fps
(with Lens)
90 fps
*1: Applicable standards IEC60825-1:1993 +A1:1997 +A2:2001, EN60825-1:1994 +A2:2001
Detection
range
V
H
34
mm
49
mm
34
mm
49
mm
31
mm
187
mm
38
mm
194
mm
5mm 9mm 5mm 9mm
Detection range (H)
Setting distance (L)
Detection range (H)
Setting distance (L)
Detection range (H)
Setting distance (L)
Detection range (H)
Setting distance (L)
Detection range (H)
Setting distance (L)
Detection range (H)
Setting distance (L)
10mm 50mm 10mm 50mm 50mm 90mm 90mm 150mm
67
mm
142
mm
115
mm
227
mm
Lighting
Ratings
Operation
environment
robustness
14 15