Panasonic PT-D5600EL Projector User Manual


 
44
Insert the power cord plug into the wall outlet and then
press the MAIN POWER switch.
Press the I button so that a picture is projected onto
the screen.
Press the MENU button to display the MAIN MENU
screen, and then press the and buttons to move
the cursor to select OPTION2.
Press the ENTER button to display the OPTION2
screen, and select SYSTEM INFORMATION with the
and buttons.
Press the ENTER button.
The SYSTEM INFORMATION screen will be displayed.
Press and hold the ENTER button on the projector or
the remote control for approximately 3 seconds.
An item LAMP TIME RESET will be added.
Select the lamp which has been replaced with the and
buttons.
LAMP1: Replace the LAMP UNIT 1
LAMP2: Replace the LAMP UNIT 2
Press the ENTER button, and when the LAMP TIME
RESET display flashes, press the ENTER button again.
The used hours of the specified lamp unit will be reset to zero.
When more than one lamp has been replaced, repeat the procedure from
step .
If the power does not turn on even after turning the MAIN
POWER switch I, turn the MAIN POWER O, confirm that
the lamp unit and door are installed correctly, and turn on
again.
Attention
MENU
PICTURE
ADVANCED MENU
OPTI0N2
TEST PATTERN
OPTION1
POSITION
LANGUAGE
LAMP TIME RESET
LAMP1
LAMP2
LAD55
LAD55L
LAD55
1433h
0h
1100h
0h
LAD55L
SYSTEM INFORMATION
ROM VERSION
HIGH
200h
TOTAL
300h
LAMP2 LOW
SET RUNTIME
300h
LAMP1 LOW
100h
100h
1. 00. 00
When the LAMP TIME RESET display flashes, the lamp
time reset can be canceled by pressing the MENU button.
The used hours of the lamp units can also be reset to zero
by taking the following action instead of steps to .
When lamp unit 1 has been replaced:
In the standby mode, press the number buttons in the
sequence of 737381, and then press the ENTER button.
When lamp unit 2 has been replaced:
In the standby mode, press the number buttons in the
sequence of 737382, and then press the ENTER button.
When the used hours have been reset, the lamp monitor
(LAMP1/LAMP2) will flash for 3 seconds.
Note
Replacing the lamp unit