Panasonic PT-EZ770Z Projector User Manual


 
Chapter 5Maintenance — Maintenance/replacement
134 - ENGLISH
f If the lamp unit is not installed properly, remove it and then push it in slowly. Pushing it in quickly or forcibly may break the connector.
Fig. 1
Fig. 2
Lamp unit fixing screws
Lamp cover fixing screw
Lamp unit
Handles
Lamp cover
1) Set the <MAIN POWER> switch to <OFF> and disconnect the power plug from the power outlet.
f Wait at least one hour and check if the lamp unit has cooled down.
2) Remove the lamp cover. (Fig. 1)
f Use a Phillips screwdriver to turn the lamp cover xing screw (x1) counterclockwise until it turns freely, and slide the lamp cover slowly
in the direction of the arrow to remove it.
f Opening the lamp cover quickly may result in falling.
3) Remove the lamp unit. (Fig. 2)
f Use a Phillips screwdriver to turn the lamp unit xing screws (x3) counterclockwise until they turn freely, and remove the lamp unit.
f Hold the handles of the lamp unit and remove it straight.
4) Push in the new lamp unit while paying attention to the insertion position.
f If the lamp unit is not installed properly, remove it and then push it in slowly. Pushing it in quickly or forcibly may break the connector.
5) Use a Phillips screwdriver to firmly tighten the lamp unit fixing screws (x3).
f Make sure to attach the lamp unit securely.
6) Attach the lamp cover.
i) Perform Step 2) in the reverse order to attach the lamp cover.
ii) Use a Phillips screwdriver to firmly tighten the lamp cover fixing screw (x1).
f Make sure to attach the lamp cover slowly and securely.
Note
f When you replace the lamp unit with new one, the projector resets the runtime of the lamp unit automatically.
Air lter unit
When the dust remains after cleaning, the lter replacement timing has come.
The Replacement Filter Unit (Model No.: ET-RFE300) is an optional accessory. To purchase the product, consult your dealer.
How to replace the air lter unit
Attention
f Make sure to turn off the power before replacing the air lter unit.
f Make sure that the projector is stable, and perform the replacement in a safe place where the unit will not be damaged even if you drop the
air lter unit.
1) Remove the air filter unit.
f Refer to “Removing the air lter unit” (x page 131).
2) Attach the optional Replacement Filter Unit (Model No.: ET-RFE300) to the projector.
f Refer to “Attaching the air lter unit” (x page 132).
Attention
f When using the projector, be sure to attach the air lter unit. If it is not attached, the projector will suck in dirt and dust causing a malfunction.