Panasonic PT-F100 Projector User Manual


 
15/16
2.47. Query Date
Hexadecimal 02h 51h 47h 44h
03h
Character Q G D
Response (Callback)
Hexadecimal 02h *y1 *y2 *y3 *y4 *m1
*m2
*d1 *D2 *w 03h
Character
Parameters
*y1—*y4: Year (4 digits)
*m1, *m2: Month (2 digits)
*d1, *d2: Day (2 digits)
*w: Day of the week (Mon = 1, Tue = 2, Wed = 3, Thu = 4, Fri = 5, Sat = 6, Sun = 7)
Set it by UTC (Coordinated Universal Time).
Example: Saturday, April 21, 2007
*y1 *y2 *y3 *y4 *m1 *m2 *d1 *D2 *w
Hexadecimal 32h 30h 30h 37h 30h 34h 32h 31h 31h
Character 2 0 0 7 0 4 2 1 1
Acceptability
SECURITY STANDBY NO SIGNAL
SHUTTER
REMOTE
Yes Yes Yes Yes Yes
2.48. Query Time
Hexadecimal 02h 51h 47h 54h
03h
Character Q G T
Response (Callback)
Hexadecimal 02h *h1 *h2 *m1 *m2 *s1 *s2 03h
Character
Parameters
*h1, *h2: Hour (2 digits)
*m1, *m2: Minute (2 digits)
*s1, *s2: Second (2 digits)
Set it by UTC (Coordinated Universal Time).
Example: 3 seconds at 3:45 p.m.
*h1 *h2 *m1
*m2
*s1 *s2
Hexadecimal 31h 35h 34h 35h 30h 33h
Character 1 5 4 5 0 3
Acceptability
SECURITY STANDBY NO SIGNAL
SHUTTER
REMOTE
Yes Yes Yes Yes Yes
2.49. Query Filter Remaining Time
Hexadecimal 02h 51h 46h 49h 3Ah 35h 03h
Character Q F I : 5
Response(Callback)
Example:1500hours
Hexadecimal 02h 31h 35h 30h
30h
03h
Character 1 5 0 0
Acceptability
SECURITY STANDBY NO SIGNAL SHUTTER
REMOTE
Yes No Yes Yes Yes
2.50. SIDE BY SIDE key (for FW100NT only)
Hexadecimal 02h 4Fh 44h 57h 03h
Character O D W
Response(Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 44h
57h 03h
Character O D W
Acceptability
SECURITY STANDBY NO SIGNAL SHUTTER
REMOTE
No No Yes No Yes
Notes:
It is invalid during FREEZE, INDEX WINDOW, and DIGITAL ZOOM