Panasonic PT-F100 Projector User Manual


 
3/16
2. Basic Control Command
Explanatory notes
Yes: Enable
No: Disable
2.1. Power ON (Lamp ON)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Character P O N
Respone (Callback)
In the period when the command can be accepted (This command in power-on condition is included)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Character P O N
Acceptability
SECURITY STANDBY NO SIGNAL
SHUTTER
REMOTE
Yes Yes Yes Yes (Yes)
Note:
• When you confirm whether to have succeeded in power-on, confirm it by QPW (Query Power) command after
receiving the callback of PON command.
• When REMOTE is effective, ER401 is returned as a response (callback).
2.2. Power OFF (Standby)
Hexadecimal 02h 50h 4Fh 46h 03h
Character P O F
Response (Callback)
In the period when the command can be accepted (This command in power-off condition is included)
Hexadecimal 02h 50h 4Fh 46h 03h
Character P O F
Acceptability
SECURITY STANDBY NO SIGNAL
SHUTTER
REMOTE
Yes Yes Yes Yes (Yes)
Notes:
• When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after
receiving the callback of POF command.
• When REMOTE is effective, ER401 is returned as a response (callback).
2.3. AUTO SETUP
Hexadecimal 02h 4Fh 41h 53h 03h
Character O A S
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 53h 03h
Character O A S
Acceptability
SECURITY STANDBY NO SIGNAL
SHUTTER
REMOTE
No No No No Yes
Note:
• This command is acceptable only when RGB1 or RGB2 is selected and RGB PC signals are input. In other cases,
ER401 is returned.
2.4. SHUTTER key
Hexadecimal 02h 4Fh 53h 48h
3Ah
*1 03h
Character O S H : *2
Parameters (*1, *2)
Shutter OFF Shutter ON
Hexadecimal 30h 31h
Character 0 1
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 53h 48h 3Ah *1 03h
Character O S H : *2
Acceptability
SECURITY STANDBY NO SIGNAL
SHUTTER
REMOTE
No No Yes Yes Yes