Paradyne 8355 Network Card User Manual


 
B. SNMP Traps
B-4 February 2003 8335-A2-GB20-70
hdsl2ShdslPerfSESThresh The severely errored seconds threshold
has been reached/exceeded for the
HDSL2/SHDSL segment endpoint
identified.
IfIndex
hdsl2ShdslInvIndex
hdsl2ShdslEndpointSide
hdsl2ShdslEndpointWirePair
hdsl2ShdslEndpointCurr15MinSES
hdsl2ShdslEndpointThreshSES
hdsl2ShdslPerfCRCanomalies
Thresh
The CRC anomalies threshold has been
reached/exceeded for the HDSL2/SHDSL
segment endpoint identified.
IfIndex
hdsl2ShdslInvIndex
hdsl2ShdslEndpointSide
hdsl2ShdslEndpointWirePair
hdsl2ShdslEndpointCurr15MinCRC
anomalies
hdsl2ShdslEndpointThreshCRC
anomalies
hdsl2ShdslPerfLOSWSThresh The LOWSW seconds threshold has
been reached/exceeded for the
HDSL2/SHDSL segment endpoint
identified.
IfIndex
hdsl2ShdslInvIndex
hdsl2ShdslEndpointSide
hdsl2ShdslEndpointWirePair
hdsl2ShdslEndpointCurr15Min
LOSWS
hdsl2ShdslEndpointThreshLOSWS
hdsl2ShdslPerfUasThresh The unavailable seconds threshold has
been reached/exceeded for the
HDSL2/SHDSL segment endpoint
identified.
IfIndex
hdsl2ShdslInvIndex
hdsl2ShdslEndpointSide
hdsl2ShdslEndpointWirePair
hdsl2ShdslEndpointCurr15MinUAS
hdsl2ShdslEndpointThreshUAS
hdsl2ShdslSpanInvalidNum
Repeaters
A mismatch has been detected between
the number of repeater/generator units
configured for a HDSL2/SHDSL line and
the actual number of repeater/generator
units discovered via the EOC.
IfIndex
hdsl2ShdslSpanConfNumRepeaters
hdsl2ShdslLoopbackFailure An endpoint maintenance loopback
command failed for an HDSL2/SHDSL
segment.
IfIndex
hdsl2ShdslInvIndex
hdsl2ShdslEndpointSide
hdsl2ShdslMaintLoopbackConfig
Table B-1. SNMP Traps (4 of 6)
Event Description Variable Bindings