Patton electronic 1060 Network Card User Manual


 
7 8
4.0 INSTALLATION
The Model 1060 is easy to install. After configuring the DIP
switches and DCE/DTE switches, connect the two twisted pairs using
one of two methods: terminal blocks or RJ-11 jack. Figure 2 (below)
shows the location of the terminal blocks and RJ-11 jack, as well as
the female DB-25, on the rear of the Model 1060.
Figure 2. Rear view of 1060 showing interface connectors
4.1 TWISTED PAIR WIRING OVERVIEW
These short range modems are designed to work in
pairs
.You
will need one at each end of a 4-wire twisted pair circuit. The pairs
must be "dry" (unconditioned) metallic wire, 19 - 26 AWG. The smaller
gauges limit distance somewhat compared with larger gauges. When
you have completed wiring for your data circuit, the pin connections
should be as shown below:
4.1.1 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS
If your two twisted pair line terminates in bare wires, strip the ends
and connect the individual leads to each Model 1060's terminal block.
Be sure the end-to-end connections follow the diagram above.
4.1.2 TWISTED PAIR CONNECTION USING RJ-11
If your two-pair cable is terminated in an RJ-11 plug, you may use
the RJ-11 jack in the back of the Model 1060 to make the connection.
The RJ-11 jack on a Model 1060 series Short Range Modem is
prewired for a standard TELCO wiring environment. To be sure you
have the right wiring, use the diagram below as a guide.
RJ-11
SIGNAL
1....................... GND
2....................... RCV-
3....................... XMT+
4........................XMT-
5....................... RCV+
6....................... GND
For proper signal crossing between two Model 1060s using RJ-11
connectors, pin-out the twisted pair cable according to the diagram
below.
SIGNAL
PIN# PIN# SIGNAL
GND
........1............6.......................GND
RCV- ........2............4.......................XMT-
XMT+........3............5.......................RCV+
XMT- ........4............2.......................RCV-
RCV+........5............3.......................XMT+
GND
........ 6............1.......................GND
Connection to ground is optional
Standard color codes—yours may be different
AT&T standard modular color codes
XMT + RCV+
XMT - RCV -
GG
RCV - XMT -
RCV + XMT +
To Shield (Optional)
}
One Pair
}
One Pair
RS-232 Interface
Made In The USA
LinePower
RX+ RX- GND TX- TX+
Powered Async. Short
Range Modem
1 - Blue
2 - Yellow
3 - Green
4 - Red
5 - Black
6 - White