Patton electronic 4552 Network Router User Manual


 
Installing the gateway router 27
SmartNode 4552 & 4562 Getting Started Guide 3 • SmartNode installation
External S-Bus power supply
Many ISDN telephone handsets require that 40-VDC power be supplied via the S-Bus connection. In other
words, they have no separate or built-in power supply. In general, point-to-multipoint ISDN BRI network ter-
minations supply line power to the S-Bus. Point-to-point configurations connected to a PBX generally do not
supply line power.
The Model 4552 does not supply S-Bus line power on the BRI ports, however, there are two options to provide
S-Bus line power:
If one of the BRI ports is connected to an ISDN NT, the power supplied by the NT is fed through to the
other BRI port.
If line power is not available from the NT, but required for connected terminals, the PM-BRI-EXT S-Bus
Phantom power supply can be used.
Table 5. PM-BRI-EXT S-Bus 40V power supply
Item Phantom Power Supply; PM-BRI-EXT
Voltage Specifications Input 230VAC, Output 40VDC
If you use a Phantom power supply other than that supplied by
Patton Electronics Co., you must ensure that it conforms to ITU
I.430 Section 9.7.3.2.2. which specifies that the maximum cur-
rent delivered shall not exceed 200mA.
The PM-BRI-EXT power supply unit is equipped with a transformer
that is specially designed for S-Bus line power. The use of a general
purpose DC power transformer may cause equipment damage.
Do not plug the Phantom power supply directly into any other port
than BRI 0/0. Installing it on the Ethernet ports could result in serious
equipment damage.