SmartNode 4630 User Manual 1 • General information
BRI 0/1
ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see
figure 2
), connects the
SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The inter-
face may be used as fallback if connected to an NT. The port can be switched
between TE and NT mode.The interface is internally terminated with 100 Ohm.
Point-to-point or point-to-multipoint configurable. If the port is in NT mode a phantom
power supply can be switched on to supply connected phones with power.
BRI 0/2
ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see
figure 2
), connects the
SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The port
can be switched between TE and NT mode.The interface is internally terminated
with 100 Ohm. Point-to-point or point-to-multipoint configurable. If the port is in NT
mode a phantom power supply can be switched on to supply connected phones
with power.
BRI 0/3
(SN4638 only)
ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see
figure 2
), connects the
SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The port
can be switched between TE and NT mode.The interface is internally terminated
with 100 Ohm. Point-to-point or point-to-multipoint configurable. If the port is in NT
mode a phantom power supply can be switched on to supply connected phones
with power.
BRI 0/4
(SN4638 only)
ISDN BRI NT/TE port, RJ-45 socket S0 (S/T) interface (see
figure 2
), connects the
SmartNode with an ISDN device over an S/T bus, e.g. a PBX or an NT. The port
can be switched between TE and NT mode.The interface is internally terminated
with 100 Ohm. Point-to-point or point-to-multipoint configurable. If the port is in NT
mode a phantom power supply can be switched on to supply connected phones
with power.
Console
Used for service and maintenance, the Console port (see
figure 2
), an RS-232 RJ-45
connector, connects the product to a serial terminal such as a PC or ASCII terminal
(also called a dumb terminal).
100-240 VAC 50-
60 Hz
Electricity supply socket for mains power cable. (see
figure 2
).
Reset
The reset button (see
figure 2
) has three functions:
•
Restart the unit with the current startup configuration—Press (for less than 1 second)
and release the Reset button to restart the unit with the current startup configuration.
•
Restart the unit with factory default configuration—Press the Reset button for
5 seconds until the Power LED (see
figure 3
on page 17) starts blinking to restart
the unit with factory default configuration.
•
Restart the unit in bootloader mode (to be used only by trained SmartNode tech-
nicians)—Starting with the unit powered off, press and hold the Reset button as
you apply power to the unit. Release the Reset button when the Power LED starts
blinking so the unit will enter bootloader mode.
Table 2. Rear panel ports (Continued)
Port Description