Patton electronic Model 1065 Network Card User Manual


 
21 22
5.5 POWER-DOWN
Turn off the Model 1065 Series by simply unplugging the AC power
cord from the wall. There is no power switch.
APPENDIX A
PATTON ELECTRONIICS MODEL 1065 SPECIFICATIONS
Transmission Format: Synchronous or asynchronous, 2-
wire/half duplex, or 4-wire/full or half
duplex
Interface: RS-232 (CCITT V.24) connection via
DB-25 female; twisted pair connection
via RJ-45
Transmission Line: 2 or 4-wire UTP, 19 - 26 AWG
Data Rates: Model 1065 - Synchronous or
asynchronous at 1.2, 1.8, 2.4, 3.6, 4.8,
7.2, 9.6, 14.4, 19.2, 28.8, 38.4, 57.6 and
64 kbps—switch selectable;
Clocking: Internal, external or receive recover
Controls: Carrier constantly “ON” or “controlled by
RTS”; RTS/CTS delay set to no
delay, 7 or 53 ms
Applications: Point-to-point or multi-point
Indicators: Mono-color LED indicators for TD, RD,
RTS & DCD; single LED indicators for
Power, Test, and Error
RTS Anti-stream Timer 12.5 sec., 50 sec., or disabled (switch
selectable); tolerance: +50%, -0
Diagnostics: V.52 compliant bit error rate pattern
(511/511E pattern) generator and
detector with error injection mode;
V.54 compliant—Local Analog Loopback
and Remote Digital Loopback, activated
by front panel switch or via RS-232
interface
Transformer Isolation: 2000 V RMS
Surge Protection: Immune to IEC-801-5 Level 2, 1kV
Temperature: -10°C to 70°C
Humidity: 100% condensing from -10°C to +30°C
Absolute humidity from +30°C to +70°C
Dimensions: 5.5” (W) X 7.5” (D) X 1.6” (H)
(13.9 cm X 19 cm X 4 cm)
Power Supply: 157-242 VAC Universal Interface