Pelco Manual C1902M (11/96) 7
Figure 3. Typical 120 VAC to 24 VAC (60 Hz) Power Supply
Typical Power Supply
To 24 VAC Terminals
On Camera
24 VAC Output
Input
120 VAC, 60 Hz
• 230 VAC power source: The 24 VAC CC4600-2X and the 230 VAC CC4600-3 must be wired to a 50 Hz source.
Figure 4. Typical 230 VAC to 24 VAC (50 Hz) Power Supply
NOTE: Cameras with 220-240 VAC power
cords are double insulated. Article 250-45 of
the National Electrical Code states that listed
products protected by a system of double insu-
lation shall not be required to be grounded.
Typical Power Supply
Input
220-240 VAC, 50 HZ
To 24 VAC Terminals
On Camera
With 240 VAC Input: Use #1 and COM
With 220 VAC Input: Use #2 and COM
#2
#1
COM
• 120 VAC power source: The 24 VAC CC4600-2 camera must be wired to a 60 Hz source.