Pelco C2410M-H Switch User Manual


 
10 C2462M-B (10/05)
Installation to Surface of a 4S Standard Electrical Box
Refer to Figure 7 for the following steps.
1. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied).
2. Connect the video cable/wires.
BNC – Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted Pair – Blue wire = Video +
Gray wire = Video -
3. Connect the power wires.
AC Operation Only – If you are wiring more than one ICS090 Camclosure to the same
transformer, connect one side of the transformer to the red wire on all units, and connect the
other side of the transformer to the black wire on all units. Failure to connect all of the units
the same way will cause the cameras to be out of phase with each other and may produce a
vertical roll when switching between cameras.
4. Attach the surface trim ring and back box to the adapter plate with the two 8-32 x 2.50-inch
screws (supplied).
Figure 7. 4S Standard Electrical Box Installation
CEILING/
WALL
4S STANDARD
ELECTRICAL BOX
OPTIONAL
ADAPTER RING
8-32 X 1.00
(SUPPLIED)
BACK BOX AND
SURFACE MOUNT
RING
8-32 X 2.50
(SUPPLIED)
Voltage Red Wire Black Wire
12 VDC + Ground
24 VAC
~~