14 C1679M (1/06)
CONNECTIONS
Connections to the FT8301A transmitter and the FR8302A receiver are made on the rear panel of the
modules and consist of the following:
• Power connection
NOTES:
– A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when
used as a standalone module. A 12 VDC power supply is provided. If a 24 VAC power
supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as
Class 2 and rated as 24 VAC, 200 mA (minimum output).
– In extreme temperature conditions, it is recommended that an industrial-rated outdoor
power supply such as the Pelco WCS1-4 power supply be used.
• Fiber connection
• Video connection (UTP or BNC)
NOTE: When connecting to the UTP connector, it is recommended that solid UTP wire rather
than stranded UTP wire be used. If stranded UTP wire is used, it is recommended that you tin
the stranded wire.
Figure 5 illustrates FT8301A transmitter connections. Figure 6 illustrates FR8301A receiver
connections.
Figure 5. FT8301A Transmitter Connections
POWER CONNECTION
FOR STANDALONE MODULE
FIBER OPTIC CABLE
COAXIAL CABLE
UTP WIRES