Pelco SX8205R Switch User Manual


 
C2626M (2/07) 15
Troubleshooting
LED indicators on the front and rear panels of the SX8205R module allow you to monitor operational
status:
The Power LED (Pelco badge) on the front panel (refer to Figure 2) allows you to monitor
operating power. Refer to Table B for information about the Power LED and associated
troubleshooting guidelines.
LED indicators on the rear panel (refer to Figure 3) allow you to monitor RJ-45 10BASE-T/
100BASE-TX port status. Refer to Table C for information about the rear-panel indicators and
associated troubleshooting guidelines.
Table B. Troubleshooting with Front-Panel Indicator
Indicator Color Meaning Possible Cause Corrective Action
Power LED (Pelco badge)
Blue Power is being
applied to the
module.
No action required.
Not lit Power is not being
applied to the
module.
Power connection is faulty. Check power connection.
If module is rack mounted,
reseat module or power
supply as necessary.
Power supply has failed. Replace power supply.
Loss of power occurs due to
tripped circuit breakers,
blown fuses, or faulty elec-
trical service.
Check circuit breakers, fuses,
or electrical service as
necessary.