Pelco TS4000 Switch User Manual


 
PELCO Manual C498M-A (9/95) 3
5.0 INSTALLATION
Many of the High Security Series enclosures come stan-
dard from the factory with a tamper switch(es) mounted
on the secured access door.
Should additional switches be required, and for
connection of those switches, please read the
following sections.
5.1 MOUNTING THE UNIT
To mount the tamper switch kit to an enclosure, per-
form the following steps:
1. Open the enclosure through the access door oppo-
site of the desired “alarmed” opening.
2. Remove the protective covering on the double-
sided tape.
3. Position the switch assembly on the fixed portion
of the enclosure with the plunger engaged with the
access door and depressed.
4. Firmly press the mounting bracket to insure full
engagement of the double-sided tape.
5. Make any minor adjustments to the switch activa-
tion point with the adjustment screw on the plunger
of the switch.
5.2 WIRING THE UNIT
The tamper switch comes with both a “Normally Open”
contact and a “Normally Closed” contact.
For a “Normally Open” circuit, use the black and white
leads. For a “Normally Closed” circuit, use the black
and red leads.