VIDEO OUTPUT
This output must be terminated with a 75-ohm load. So, if you loop the output through monitors or other accessories, be sure
their terminations are set to HI-Z. Only the last unit on the line should have its termination set to 75 ohms.
SYNC OUTPUT (H DRIVE – V DRIVE BNC CONNECTORS)
When a camera having random interlace is used as the master camera, the second camera must be synchronized by using the
H Drive and V Drive outputs. Refer to Figure 2.
POWER
The supplied five-foot (1.5 m), three-wire line cord with grounded plug complies with safety standards. The unit operates over
a voltage range from 95 to 230 VAC, 50/60 Hz and draws about three watts at 120 VAC.