Pelco WCSI-4 Power Supply User Manual


 
C561M-D (11/03) 5
FUSE INSTALLATION
The WCS1-4 power supply is shipped from the factory with a 1.6-amp fuse installed for 100/120 VAC
input power. To use input power of 230 VAC, change the 1.6-amp fuse to a 500-milliamp fuse (supplied).
To change the fuse remove the lid to the fuse holder (refer to figure 4) located inside the power
supply and then install the new fuse. Store extra fuses (supplied) in the spare fuse holders.
INPUT POWER WIRING
WARNING: The WCS1-4 does not have an on/off switch. Turn off power at the circuit
breaker before wiring the power supply.
To install the input power wires to the WCS1-4 power supply, refer to Figure 4 and do the
following:
1. Determine the size of the input wire needed.
2. Bring the wiring into the WCS1-4 through the conduit fitting.
3. Attach the neutral input power wire to the 100V, 120V, or 230V NEUTRAL connection on the
Primary Line Input connector strip. Attach the hot wire to the LINE connection on the same
strip.
4. Attach the input ground wire to the No. 6 ground stud, located between the conduit holes, and
tighten the wire with the nut and washer (supplied).