Perle Systems S-10G-XTX Network Router User Manual


 
Perle S- 10G Media Converter Installation Guide
8
Note: If the remote media converter is not a Perle S-10G then the remote
media converter will need to be put into loopback mode. See the
documentation that came with that media converter.
Sequence of Events
1. The Local S-10G sends the Remote S-10G a signal to go into
loopback mode.
2. The Remote S-10G media converter turns on loopback mode.
3. Built In Test data is sent from the Local S-10G media
converter to the Remote S-10G media converter.
4. The Remote S-10G media converter loops the received data
back to the Local S-10G media converter.
5. Any test errors detected are displayed with the LEDs on the
front of the Local S-10G media converter.
6. The Built in Link Tests continue to run until Switch 1 on the
Local S-10G media converter is set to Data mode.
Port Selection (Switch 3 – Test Mode)
Switch Position Port
Up (default) 1
Down 2
Fiber Fault Alert (Switch 3 – Data Mode)
Switch Position Mode
Up (default) Enabled
Down Disabled
Enabled: If the media converter detects a loss of fiber, the media
converter will immediately notify the fiber link partner that an error
condition exists.
If the remote media converter is set up for Fiber Fault Alert (FFA)
Enabled and the local media converter is set up with Smart Link
Pass-Through, a loss of fiber link on either the transmit or receive
line will be passed through to the other fiber connection.
Disabled: The media converter will not monitor for fiber fault.