Philips 107B7 Computer Monitor User Manual


 
17” CDT Color Monitor 107B7
70
2.7.4 Monitor status information
Self-test feature - “CHECK SIGNAL CABLE” message appears when video cable
is disconnected.
Out of scan range - “FREQUENCY IS OUT OF RANGE” appears when input H-sync
or V-sync out of range.
Resolution & H/V input - Shown in OSD menu “EXTRA CONTROLS”.
2.7.5 Power connector
AC socket 3-pin IEC-320-C13, at rear side.
2.7.6 Video input connector/Video cable
1.5m non-detachable fly-in video cable with D-Sub 15 pin male blue connector, pin assignment of D-Sub:
Pin
Function
1 Red video
2 Green video
3 Blue video
4 GND
5 Self test
6 Red GND
7 Green GND
8 Blue GND
9 +5V (Supply from PC for DDC circuit)
10 Sync GND
11 GND
12 DDC serial data
13 H-sync
14 V-sync
15 DDC serial clock
H-sync line impedance must be within 50 ~ 70 (TDR measurement).
V-sync line impedance should be within 40 ~ 70 (TDR measurement).
RGB signal lines must be 75 ± 5% coaxial.
R, G, B coaxial shield must connect to D-Sub metal shell.
3. Front Of Screen Performance
3.1 CRT characteristics