The monitor is intended for use with Medical
Equipment to display alpha, numerical and
graphical data. The subject equipment Philips
monitor is powered by an external recognized
AC/DC adapter (IEC/EN60601-1).
1.1 Safety Information
Power adapter
This adapter (Manufacture: Philips, Model:
TPV-15W-05) is a forming part of the medical
device.
The connection of external equipments
External equipment intended for connection to
signal input/output or other connectors, shall
comply with relevant UL / IEC standard (e.g. UL
60950 for IT equipment, UL 60601 and ANSI/
AAMI ES606011 / IEC 60601 series for systems
– shall comply with the standard IEC 60601-
1-1, Safety requirements for medical electrical
systems. Equipment not complying with MOPP
of ANSI/AAMI ES606011 shall be kept outside
the patient environment, as dened in the
standard.
Disconnecting Device
The mains plug or appliance coupler is used as
the disconnect device, the disconnect device
shall remain readily operable. Always completely
disconnect the power cord set from your
product whenever you are working or cleaning
on it. Do not make connections while the
power is on, because a sudden rush of power
can damage sensitive electronic components.
Classication
Degree of protection against the ingress of
water: IPX0
Equipment not suitable for use in the
presence of a flammable anesthetic mixture
with air or with oxygen or nitrous oxide.
(Non AP or APG Category)
Mode of operation: Continuous
Type of protection against electric shock:
Class II equipment
No applied part.
Shutdown Procedure
We strongly recommended that you should
shut down the system before you start to clean
any single components.
Please follow the steps below.
Close all application programs
Close operating software
Turn off power switch
Disconnect power cord set
Remove all devices
Safety Symbol Description
The following safety symbols are the further
explanations for your reference.
Medical component
With respect to electric shock, re and
mechanical hazards only in accordance with
ANSI/AAMI ES60601-1, and CAN/CSA
C22.2 NO. 60601-1
Attention, consult ACCOMPANYING
DOCUMENTS.
Attention, consult ACCOMPANYING
DOCUMENTS.
Type of protection against electric shock:
Class II equipment
Type of Current- AC
European Community Approval
The monitor complies with the 93/42/
EEC and 2007/47/EC and conforms to the
applicable following standards: EN60601-
1, EN 60601-1-2, EN 61000-3-2 and EN
61000-3-3.
TUV Type Testing Approval
The monitor complies with the EN60601-1
and IEC60601-1 of European Standards.
Note
Caution: Use suitable mounting apparatus
to avoid risk of injury.
Use a power cord that matches the voltage
of the power outlet, which has been
approved and complies with the safety
standards of your particular country.
Keeping to clean your monitor by monthly.