Planet Technology GSW-2404SF Switch User Manual


 
System Description
Defines the user-defined device description
Password -
This function provides administrator to secure Web login
Inactivity Timeout –
Specifies a time period for the user login. The web interface will be auto logout if
there’re no actions from the login user.
The default value is 300 seconds; 0 means no inactivity time limit.
SNMP Enable – Enable or Disable the SNMP function of the device. While set to enable, the
manager could remotely get the interface status and received the traps
information.
SNMP Trap
destination –
The Trap function enables the Switch to monitor the Trap through the Web Switch
Utility, set the Trap IP Address of the manager workstation where the trap to be
sent
SNMP Read
Community –
Functions as a password and used to authenticate the access right of the device.
The Read Community is restricted to read-only, for all MIBs except the
community table, for which there is no access.
SNMP write
Community –
Functions as a password and used to authenticate the access right of the device.
The Write Community accesses the device both read and write - configure to the
device via SNMP.
SNMP Trap
Community –
Identifies the community string of the trap manager
Table 4-2 Description of the Misc Configuration
#Note:
After change the default password, if you forget the password. Please press 5 seconds and release
the “Reset” button in the front panel of GSW-1602SF/GSW-2404SF/GSW-2416SF, the current
setting includes VLAN, will be lost and the GSW-1602SF/GSW-2404SF/GSW-2416SF will restore to
the default mode.
-15-