Planet Technology IDL-2402 Switch User Manual


 
Alarm
This option allows you to configure the RMON alarm setting. This table controls the
conditions on which alarms occur. Click on New to create an entry. To modify an entry,
click on the index to select the entry, type in new value, and then click on Modify. To
delete an entry, click on the index to select the entry and then click on Delete.
RMON Alarm setup
Label Description
Interval
The interval in seconds over which the data is sampled and compared with the
rising and falling thresholds. Value range: 0~2147483647 (0: disable).
Owner RMON alarm owner (max 31 characters).
OID Variable
Click on the drop-down list to select ETH statistics variable and index of ETH
Statistics table entries.
SampleType
RMON alarm sample type includes:
ABSOLUTE: the value of the selected variable will be compared directly with the
thresholds at the end of the sampling interval.
DELTA: the value of the selected variable at the last sample will be subtracted
from the current value, and the difference compared with the
thresholds.
- 199 -