Polycom DOC2558A Server User Manual


 
Chapter 1- Hardware Description
1-30
Types of Ejector Levers on RMX Components
On the RMX, 2 types of ejector levers can be attached to the cards:
An all metal (silver) lever
A modified PMC compatible ejector lever covered by plastic caps
with a lock catch
Using the All Metal Ejector Lever
This ejector lever can be moved to 3 positions:
Closed - The ejector levers are fully retracted and pushed up against
the card’s panel
Partially Open - For card powering down mode. Partially open the
ejector lever(s) until the blue HS LEDs on the card and the Control
Unit start flashing. When the HS LED is constantly lit the card is in a
powered down mode and you can remove the card.
Fully Open - The card is released from the MCU housing
Using the Modified PMC Compatible Ejector Lever
This ejector lever can be moved to 3 positions:
Closed/Locked - Ejector lever(s) are gently pushed up against the
card’s panel and is locked. Ensure that the lock catch is in the
standard closed position (shifted to the right as shown below).
Warning!
Once the removal sequence is initiated and the HS led flashes, the process
cannot be terminated when activated.