Polycom se200 Webcam User Manual


 
ReadiManager
®
System Setup
Polycom, Inc. 1-7
Connect to the ReadiManager SE200 Appliance
You can configure the ReadiManager SE200 appliance through a serial port or
ethernet port connection. These sections give the two connection procedures.
To connect to the ReadiManager SE200 appliance through the serial port
1 With an RS-232 serial cable, connect a computer to the 9-pin, serial port on
the ReadiManager SE200 appliance.
2 Connect the ReadiManager SE200 appliance to the LAN2 port.
3 Turn on the computer and the ReadiManager SE200 appliance.
4 From the Start menu, select All Programs > Accessories >
Communications> HyperTerminal.
5 In the Connection Description dialog box, enter SE200 in the Name field,
accept the default icon selection, and click OK.
6 In the Connect To dialog box, select the appropriate comport number
from the Connect using menu.
7 In the Properties dialog box, enter these values for port settings and click
OK.
Bits per second: 19200
Data bits: 8
—Parity: None
—Stop bits: 1
Flow control: None
8 Click OK.
9 In the SE200 - HyperTerminal window, press Enter.
10 From the SE200 Menu, enter 2 for System Setup and press Enter.
11 Enter these values from Table 1-1, First-Time Setup Worksheet.
a Enter
1
for DNS Server IP and press Enter. At the prompt, enter the
DNS Server IP address and press Enter.
Note
If you do not connect to the LAN port now, the system IP address, DNS IP address,
and Default Gateway will show 0.0.0.0.