Battery Start Feature
The Battery Start feature allows you to turn on the UPS when utility
power is not available. The battery-start range is up to about 40% of
nominal input; otherwise, the UPS displays an input voltage fault and
the alarm beeps.
RJ-11 or RJ-45 Surge Protectors
The RJ-11 or RJ-45 surge protectors are located on the side panel and
are labeled IN and OUT. This feature accommodates an RJ-11 connector
that provides protection for modems, fax machines, or other
telecommunications equipment. As with most modem equipment, it is
not advisable to use this jack in digital PBX (Private Branch Exchange)
environments.
Low voltage models can also accommodate a single RJ-45 (10BaseT)
network connector.
NOTE DO NOT connect any network equipment to the 230V models; only telephone or
fax/modem protection is available for 230V models.
1. Connect the input connector of the equipment you are
protecting to the jack labeled IN.
2. Connect the output connector to the jack labeled OUT.