Printek MtP300 Printer User Manual


 
Printek Emulation
Elements per symbol: 4 (2 bars, 2 spaces)
Character density: 14.5 CPI
Bar width: 0.25mm
Characters
Note: When specifying the bar code height that h represents the total height including a 1.25mm drop bar
pattern printed after the barcode pattern.
Example 1: The following escape sequence will print a UPC-A bar code containing “12345678901” that is
30mm high followed by human readable text. Note that a check digit “9” is also sent, but will be ignored and
recalculated by the printer.
Escape Sequence: ESC Z 4 12 240 1 2 3 4 5 6 7 8 9 0 1 9
Hexadecimal: 1B 5A 34 0C F0 31 32 33 34 35 36 37 38 39 30 31 39
Example 2: The following escape sequence will print a UPC-E bar code containing “1234567” that is 30mm
high followed by human readable text.
Escape Sequence: ESC Z 4 7 240 1 2 3 4 5 6 7
Hexadecimal: 1B 5A 34 07 F0 31 32 33 34 35 36 37
Example 3: The following escape sequence will print an EAN/JAN-8 bar code containing “1234567” that is
30mm high followed by human readable text. Note that a check digit “9” is also sent, but will be ignored and
recalculated by the printer.
Escape Sequence: ESC Z 4 8 240 1 2 3 4 5 6 7 9
Hexadecimal: 1B 5A 34 08 F0 31 32 33 34 35 36 37 39
Example 4: The following escape sequence will print an EAN/JAN-13 bar code containing “123456789012”
that is 30mm high followed by human readable text. Note that a check digit “9” is also sent, but will be ignored
and recalculated by the printer.
Escape Sequence: ESC Z 4 13 240 1 2 3 4 5 6 7 8 9 0 1 2 9
Hexadecimal: 1B 5A 34 08 F0 31 32 33 34 35 36 37 38 39 30 31 32 39
Interleaved 2 of 5 Specifications
Description: Each symbol starts with Leading Quiet Zone, followed with Start Symbol, Data
Symbols, ending with Stop Symbol and Trailing Quiet Zone.
Character set: numeric pairs.
Elements per symbol: 10 (5 bars, 5 spaces)
Character density: 11.11 CPI
Bar width: 0.25mm
15