SANbox 9000 Series Stackable Chassis Switch HyperStack Cable Installation Guide
59238-01 A 5
D
Confirm HyperStack Operation
Confirm that the ICC port Logged-In LEDs on all
CPU blades are illuminated. This indicates that
the switches are communicating.
1. Logged-In LEDs
Enter the Show Interconnect command to
confirm each ICC port is online.
SANbox #> show interconnect
Blade ID ICC ID State LSDB ID ISOREASON
-------- ------ ----- ------- ---------
CPU0 ICC0 Online 0x1000 NotApplicable
ICC1 Online 0x1001 NotApplicable
CPU1 ICC0 Online 0x1010 NotApplicable
ICC1 Online 0x1011 NotApplicable
Enter the Show Fabric
command to confirm that
both SANbox 9000 Series
switches are in the fabric.
SANbox #> show fabric
Domain WWN Enet IP Addr FC IP Addr SymbolicName
------ --- ------------ ---------- ------------
*1 (0x01) 10:00:00:c0:dd:07:4a:e8 10.20.83.203 0.0.0.0 SANbox 9000
2 (0x02) 10:00:00:c0:dd:00:6a:2d 10.20.68.12 0.0.0.0 SANbox 9000
* indicates principal switch
1
1