Q-Logic SANBOX Switch User Manual


 
5 – Fibre Alliance MIB Objects
5-48 59047-03 B
A
connUnitPortHWState (1.3.6.1.3.94.1.10.1.23)
The hardware detected state of the port.
Syntax
INTEGER {
unknown(1),
failed(2), - port failed diagnostics
bypassed(3), - FCAL bypass, loop only
active(4), - connected to a device
loopback(5), - Port in external loopback
txfault(6), - Transmitter fault
noMedia(7), - media not installed linkDown
(8) - waiting for activity (rx sync)
}
Access
read-only
Status
mandatory
Return Value
Refer to Table 5-30 for connUnitPortHWState port state return values.
Table 5-30. ConnUnitPortHWState Port State Return Values
Port State Return Value
If DiagStatus = Failed Failed (2)
If SFP = Not Installed NoMedia (7)
If SyncStatus = SyncAcquired Active (4)
If SyncStatus = SyncLost LinkDown (8)
Other Unknown (1)