Q-Logic SANBOX Switch User Manual


 
5 – Fibre Alliance MIB Objects
5-2 59047-03 B
A
FcEventSeverity INTEGER{
unknown (1),
emergency (2),
alert (3),
critical (4),
error (5),
warning (6),
notify (7),
info (8),
debug (9),
mark (10) - All messages logged
}
FcUnitType INTEGER {
unknown(1)
other(2) - none of the following
hub(3) - passive connectivity unit supporting loop protocol.
switch(4) - active connectivity unit supporting multiple protocols.
gateway(5) - unit that converts not only the interface but also
encapsulates the frame into another protocol. The assumption is
that there is always two gateways connected together. For
example, FC <-> ATM.
converter(6) - unit that converts from one interface to another. For
example, FC <-> SCSI.
hba(7) - host bus adapter
proxy-agent(8) - software proxy-agent
storage-device(9) - disk, cd, tape, etc.
host(10) - host computer
storage-subsystem(11) - raid, library, etc.
module(12) - subcomponent of a system
swdriver(13) - software driver
storage-access-device(14) - Provides storage management and
access for heterogeneous hosts and heterogeneous devices
wdm(15) - waveform division multiplexer
ups(16) - uninterruptable power supply
}
Table 5-1. FA-MIB Textual Substitutions (Continued)
Description Syntax