Quantum Audio Scalar 50 Network Card User Manual


 
Quantum Scalar 50 Tape Drive Installation Instructions
Document 81-81769-01 B01
September 2007
Setting the Tape Drive SCSI ID 11
Setting the Tape Drive SCSI ID 0
The next step in the installation procedure is to set the required SCSI ID for
the new tape drive.
There are two ways to set the tape drive SCSI ID:
Setting the SCSI ID Using the OCP
Setting the SCSI ID from the Remote Management Pages
Setting the SCSI ID
Using the OCP
0
To set the tape drive SCSI ID on an Scalar 50 Series library with an LCD:
1 From the operator control panel (OCP), press
Setup from the Home
screen. The OCP displays the
Setup screen (see figure 9):
Figure 9 Setup Screen
2 Use the up and down arrows to highlight Cabinet and press Enter.
The
Cabinet screen displays (see figure 10):
Figure 10 Library Options
Screen
3 Use the up and down arrows to highlight Host bus and press Enter.
The
Host bus screen displays (see figure 11):
Note: The library assigns SCSI IDs based on the drive order. Drive bay
1 = SCSI ID 1, drive bay 2 = SCSI ID 2, and so forth. It is only
necessary to perform the steps in this section if you need to set the
tape drive SCSI ID to an ID other than the default.
Enter