Renesas HD74LV2GT04A Power Supply User Manual


 
HD74LV2GT04A
Rev.2.00, Oct.14.2003, page 4 of 7
Recommended Operating Conditions
Item Symbol Min Max Unit Conditions
Supply voltage range V
CC
3.0 5.5 V
Input voltage range V
I
05.5V
Output voltage range V
O
0V
CC
V
—6 V
CC
= 3.0 to 3.6 VI
OL
—12 V
CC
= 4.5 to 5.5 V
—–6 V
CC
= 3.0 to 3.6 V
Output current
I
OH
–12
mA
V
CC
= 4.5 to 5.5 V
0 100 V
CC
= 3.0 to 3.6 VInput transition rise or fall rate t / v
020
ns / V
V
CC
= 4.5 to 5.5 V
Operating free-air temperature T
a
–40 85 °C
Note: Unused or floating inputs must be held high or low.
Electrical Characteristic
Ta = –40 to 85°C
Item Symbol V
CC
(V) * Min Typ Max Unit Test condition
3.0 to 3.6 1.5 V
IH
4.5 to 5.5 2.0
3.0 to 3.6 0.6
Input voltage
V
IL
4.5 to 5.5 0.8
V
3.3 0.10 Hysteresis voltage V
H
5.0 0.15
VV
T
+
– V
T
Min to Max V
CC
–0.1 I
OH
= –50 µA
3.0 2.48 I
OH
= –6 mA
V
OH
4.5 3.8 I
OH
= –12 mA
Min to Max 0.1 I
OL
= 50 µA
3.0 0.44 I
OL
= 6 mA
Output voltage
V
OL
4.5 0.55
V
I
OL
= 12 mA
Input current I
IN
0 to 5.5 ±1 µAV
IN
= 5.5 V or GND
Quiescent
supply current
I
CC
5.5 10 µAV
IN
= V
CC
or GND,
I
O
= 0
I
CC
5.5 1.5 mA One input V
IN
= 3.4 V,
other input V
CC
or GND
Output leakage current I
OFF
0—5µAV
I
or V
O
= 0 to 5.5 V
Input capacitance C
IN
5.0 3.0 pF V
IN
= V
CC
or GND
Note: For conditions shown as Min or Max, use the appropriate values under recommended operating