Renesas HD74LV2GT04A Power Supply User Manual


 
HD74LV2GT04A
Rev.2.00, Oct.14.2003, page 5 of 7
Switching Characteristics
V
CC
= 3.3 ± 0.3 V
Ta = 25°C Ta = –40 to 85°C
Item Symbol
Min Typ Max Min Max
Unit
Test
Conditions
FROM
(Input)
TO
(Output)
6.5 12.0 1.0 14.0 C
L
= 15 pFPropagation
delay time
t
PLH
t
PHL
11.0 15.0 1.0 17.0
ns
C
L
= 50 pF
A Y
V
CC
= 5.0 ±0.5 V
Ta = 25°C Ta = –40 to 85°C
Item Symbol
Min Typ Max Min Max
Unit
Test
Conditions
FROM
(Input)
TO
(Output)
5.0 7.0 1.0 8.0 C
L
= 15 pFPropagation
delay time
t
PLH
t
PHL
8.0 10.5 1.0 12.0
ns
C
L
= 50 pF
A Y
Operating Characteristics
C
L
= 50 pF
Ta = 25°C
Item Symbol V
CC
(V)
Min Typ Max
Unit Test Conditions
Power dissipation
capacitance
C
PD
5.0 10.0 pF f = 10 MHz
Test Circuit
Pulse
generator
50
C
L
Input
Output
V
CC
L
Note: C includes probe and jig capacitance.