Renesas M16C/6NN Network Card User Manual


 
M306NKT-EPB User’s Manual 3. Usage (How to Use the Emulator Debugger)
REJ10J0519-0200 Rev.2.00 Oct. 16, 2006 Page 49 of 104
2. Specifying the communication interface
Specifying the communication interface (LPT)
- For selecting the LPT communication, click the radio button “LPT”
of the MCU tab.
- For the Type area, specify LPT interface communication mode to be
used. When you use the emulator debugger for the first time,
select “AUTO”.
- Specify the I/O address of the parallel port at the I/O address area.
- For BIOS setup, the following addresses are available.
- 378h
- 278h
Specifying the communication interface (LAN)
- For selecting the LAN communication, click the radio button
“LAN” of the MCU tab.
- Specify the IP address of the emulator at the IP address area.
- Specify the IP address by one byte of decimal number separating
each four bytes with a period.
- Specify the port number at the Port area.
[Notes]
When you are using the LAN communication for the first time, connect
the emulator through other than LAN communication interface and set
the IP address, or use the SETIP utility included with your product to
set the IP address.
For details about the SETIP utility, refer to the on-line manual of your
emulator debugger.
Specifying the communication interface (USB)
- For selecting the USB communication, click the radio button “USB”
of the MCU tab.
- The emulators connected by a USB cable are shown at Serial No.
area.
- Select the serial No. of the emulator you are going to connect.
[Notes]
When you are using USB communication for the first time, you must
install the USB driver first.
The USB devices are detected when you turn on the power for the
emulator, and a wizard for installing the corresponding device driver
will automatically be started. Follow the instructions of the wizard to
complete installation.