Renesas M34282T5-OPT Network Card User Manual


 
( 7 / 38 )
IMPORTANT
Notes on Difference between Actual MCU and Emulator:
Emulator operation differs from that of a mask MCU as listed below. For details refer to "5.
Precautions to Be Taken When Debugging".
(1) Reset condition
(2) Initial values of internal resource data at power-on
(3) Internal memory (ROM and RAM) capacities, etc.
(4) System clock
(5) Operation of the watchdog timer function
(6) Real-time capability of timer
(7) Operation in power-down mode
(8) Pulldown transistor control
(9) Port I/O timing and characteristics
(10) Low-power detection function
Therefore, always be sure to evaluate your system with an evaluation MCU (OTP version). Also,
be sure to perform board-mounted evaluation with ES (Engineering Sample) version MCU to make
final confirmation of device operation before starting mask production.
Notes on Connecting Target System:
When connecting the target system, be sure to shut OFF the power of the emulator and target
system.
•When connecting the emulator probe, be careful of its orientation.
When connecting the emulator probe, be careful of a warp of the cable. The warp may cause a break
in the wire.
Note on Target System:
The operation voltage of the M34282T5-OPT is +3.0 V. Therefore the target's supply voltage
should be in the range of +3.0 V ±10%.
Note on System Clock:
The maximum operating frequency of the M34282T5-OPT is 4.0 MHz (STCK = f(XIN)/8) or 500
kHz (STCK = f(XIN)). When the instruction clock is set to f(XIN), set the system clock frequency
of the M34282T5-OPT to 500 kHz or less.