Renesas M3T-FLX-120NSE Computer Hardware User Manual


 
(3/4)
5. Connection Procedure (See Figure 3)
The procedure for connecting the M3T-FLX-120NSE is shown
below.
(1) Mount the NQPACK120SE on the target system.
(2) Attach the YQPACK120SE on the NQPACK120SE.
(3) Secure the four corners of the YQPACK120SE with the
YQ-GUIDE's.
Do not use the screws included with the
YQPACK120SE for fixing the YQPACK120SE.
The screwdriver included with the NQPACK120SE is
used for fixing the HQPACK120SE. Do not use if for
fixing the YQ-GUIDE's.
(4) Connect the probe of the emulation pod to the
M3T-FLX-120NSE.
(5) Attach the M3T-FLX-120NSE on the YQPACK120SE.
Figure 3 Connection procedure of the M3T-FLX-120NSE
6. External Dimensions and a Sample Foot Pattern
Figure 4 External dimensions and a sample foot pattern of the M3T-FLX-120NSE
YQ-GUIDE (x4)
(1)
(2)
(3)
(5)
(4)
Be sure to use a
slotted screwdriver.
Probe of emulation pod
M3T-FLX-120NSE
YQPACK120SE
NQPACK120SE
120-pin 0.4-mm-pitch
(120P6R-A) foot pattern
: No. 1 pin
Be sure to align the pins.
55.0 21.8
40.0
5.3
0.225
0.4
13.0
17.0
13.0
17.0
Unit: mm
16.5
40a
40b
1a
1b
CN2
M3T-FLX-120NSE REV.A
60 31
30
1
61
90
91 120
CN1 MADE IN JAPAN
40a
40b
1a
1b
CN1
CN2