(3/4)
5. Connection Procedure (See Figure 3)
The procedure for connecting the R0E53035ACFJ50 is shown
below.
(1) Mount the NQPACK052SB on the user system.
(2) Attach the YQPACK052SB on the NQPACK052SB.
(3) Secure the four corners of the YQPACK052SB with the
YQ-GUIDEs.
● Do not use the screws included with the
YQPACK052SB for fixing the YQPACK052SB.
● Do NOT use the screwdriver included with the
NQPACK052SB for fixing the YQ-GUIDEs. That is
used only for the HQPACK052SB.
(4) Mount the R0E53035ACFJ50 on the YQPACK052SB.
(5) Connect the flexible cable R0E001000FLX10 of the
emulator to the R0E53035ACFJ50.
(1)
(2)
(3)
(4)
(5)
Use a slotted screwdriver.
●: No.1 pin
Be sure to align the pins.
52-pin 0.65mm pitch
foot pattern
YQPACK052SB
NQPACK052SB
YQ-GUIDE (×4)
R0E53035ACFJ50
Flexible cable
R0E001000FLX10
Figure 3 Connection procedure of the R0E53035ACFJ50
6. External Dimensions and a Sample Foot Pattern
24.00
38.00
9.00
13.00
9.00
13.00
0.65
0.40
Unit: mm
16.50
2.15
CN1
1
50
51
100
TP1
TP2
R0E53035ACFJ50
REV.A
MADE IN JAPAN Pb Free
2.15
9.15
9.15
Figure 4 External dimensions and a sample foot pattern of the R0E53035ACFJ50