RuggedCom RS900W Switch User Manual


 
18
2008 RuggedCom Inc. All rights reserved Rev103
3.8 Fiber Optical Port Specifications
Order
Code
Speed
Standard
Mode /
Connector
Tx
(nm)
Cable
Type
(um)
Tx
min
(dBm)
Tx
max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Typical
Distance
(km)
Power
Budget
(dB)
MJ 100FX MM/MTRJ 1300 50/125 -22.5 -14 -33.5 -14 2 11
62.5/125 -19 -14 -33.5 -14 2 14.5
MC 100FX MM/SC 1300 50/125 -22.5 -14 -33.9 -14 2 11.4
62.5/125 -19 -14 -33.9 -14 2 14.9
MT 100FX MM/ST 1300 50/125 -22.5 -14 -33.9 -14 2 11.4
62.5/125 -19 -14 -33.9 -14 2 14.9
ML 100FX MM/LC 1310 62.5/125 -19 -14 -32 -14 2 13
T2 100FX SM/ST 1310 9/125 -15 -7 -34 -3 20 19
L2 100FX SM/LC 1300 9/125 -15 -8 -38 -3 20 23
C2 100FX SM/SC 1300 9/125 -15 -8 -31 -7 20 16
L5 100FX SM/LC 1310 9/125 -5 0 -35 -3 50 30
C5 100FX SM/SC 1310 9/125 -5 0 -34 -3 50 29
L9 100FX SM/LC 1310 9/125 0 5 -37 0 90 37
C9 100FX SM/SC 1310 9/125 5 0 -37 0 90 42
Table 12 - Fiber Optic Port Specifications
NOTES:
1. All values listed are average values
2. To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.
3. Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and
splices. Please consult RuggedCom sales associates when determining maximum segment distances.