3
PRODUCT FEATURES
ISH1
NEWMARKET, NH USA
PROGRAM OPTIONS
0=DOWN / 1=UP
DOOR BELL CHIME
DS1
NONE = 000
CHIME 1 = 001
CHIME 2 = 010
CHIME 3 = 011
CHIME 4 = 100
CHIME 5 = 101
CHIME 6 = 110
CHIME 7 = 111
SWITCH 1-3
HUB 1 = 000
HUB 2 = 001
HUB 3 = 010
HUB 4 = 011
HUB 5 = 100
HUB 6 = 101
HUB ID
FIRMWARE
UPDATE PORT
MADE IN CHINA
MIN MAX
DOORBELL CHIME
GAIN
1
3 5 DOOR
1
246
DOOR 2
15VDC
3.5A MAX
LINK
OUTIN
DS2
1-3 = DOOR 1 CHIME
SWITCH 4 = CHIME VOLUME
UP = 50% MAX KEYPAD OUTPUT
DOWN = KEYPAD ADJUSTABLE
5-7 = DOOR 2 CHIME
8 = NOT USED
#
4
UPDATE
RUN
1
2 3
4
5
67
8
1
2
3
4
5
6
7
8
POWER INPUT – For connecting model ISPS power
adapter
DOORBELL CHIME GAIN CONTROL – For adjusting
overall chime volume
DOORBELL CHIME SWITCHES – For assigning
chimes to door 1 and door 2
HUB ID SWITCHES – For assigning hub ID number
LINK PORTS – For connecting multiple ISH1 hubs
FIRMWARE UPDATE PORT – For updating device
firmware from a connected computer
DOOR STATION PORTS – For connecting ISK3 door
stations
ZONE PORTS – For connecting ISK1 or ISK2 zone
keypads