Samsung DP15HS/HT Computer Monitor User Manual


 
4-2-6 Trapezoid Adjustment
CONDITIONS
Scanning frequency: 68 kHz/85 Hz (17Ó)
54 kHz/85 Hz (15Ó)
Display image: Crosshatch pattern
Brightness: Maximum
Contrast: Maximum
Use control bar after selecting ÒTRAPEZOIDÓ in
left menu to make the image area rectangular.
Figure 4-4. Trapezoid
4-2-7 Pinbalance Adjustment
CONDITIONS
Scanning frequency: 68 kHz/85 Hz (17Ó)
54 kHz/85 Hz (15Ó)
Display image: Crosshatch pattern
Brightness: Maximum
Contrast: Maximum
Figure 4-5. Pinbalance
Use control bar after selecting ÒPINBALANCEÓ in
left menu to optimize the image.
4-2-8 Parallelogram Adjustment
CONDITIONS
Scanning Frequency: 68 kHz/85 Hz (17Ó)
54 kHz/85 Hz (15Ó)
Display image: Crosshatch pattern
Brightness: Maximum
Contrast: Maximum
Use control bar after selecting ÒPARALLELÓ in
left menu to make the image area rectangular.
Figure 4-6. Parallelogram
4-2-9 Side Pincushion Adjustment
CONDITIONS
Scanning frequency: 68 kHz/85 Hz (17Ó)
54 kHz/85 Hz (15Ó)
Display image: Crosshatch pattern
Use control bar after selecting ÒPINCUSHIONÓ in
left menu to straighten the sides of the image area.
4-2-10 Tilt Adjustment
CONDITIONS
Scanning Frequency: 68 kHz/85 Hz (17Ó)
54 kHz/85 Hz (15Ó)
Display image: Crosshatch pattern
Brightness: Maximum
Contrast: Maximum
Use control bar after selecting ÒROTATIONÓ in
left menu to correct the tilt of the display.
4-2-11 Degauss
No adjustments are available for the degaussing
circuit. The degaussing circuit can effectively
function only once per 30 minutes.
4-2-12 To Delete the User Mode Data
To delete the adjustment data from the user
modes, click Ò@4: USER DELETEÓ in right ment.
4-2-13 Save the Data
To save the adjustment data for a mode, press
Ò@3: ALL MODE SAVEÓ in right ment.
4 Alignment and Adjustments
DP15H*/DP17L* 4-5
| A - B | < 4 mm
A
4 mm
B
B
A
D1 D2 D1
| C1 |, | C2 | 2.0 mm, | D1 |, | D2 | 2.0 mm.
Figure 4-7. Pincushion
C2
C1
D1 D2