SPECIFICATIONS
Signal format : Based on NTSC color signal standard (MPX-CD162)
Based on NTSC B/W signal standard (MPX-MD162)
Camera signal input synchronization : Asynchronous
Camera input terminals (IN) : VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 16
Camera output terminals (OUT) : Throughput of each input, 1.0 Vp-p/75 Ω, BNC connector x 16
VCR input terminal (VCR IN)
•
Composite input : VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 1
•
S-VHS input terminal (S-VIDEO VCR IN): Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD162 only)
Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.286 Vp-p/75 Ω,
unbalanced
VCR output terminal (VCR OUT)
•
Composite output : VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 1
•
S-VHS output terminal (S-VIDEO VCR
OUT)
: Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD162 only)
Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.286 Vp-p/75 Ω,
unbalanced
Monitor 1 output terminal (MONITOR OUT 1) : VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 1
Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD162 only)
Y signal: 1.0 Vp-p/75 Ω, unbalanced, synchronous; C signal: 0.286 Vp-p/75 Ω,
unbalanced
Camera live picture or VCR playback picture signal output: full screen, sequential
display, Multi-display screen
Monitor 2 output terminal (MONITOR OUT 2) : VS/VBS, 1.0 Vp-p/75 Ω, BNC connector x 1
Camera live picture signal output: full screen (can be set in (MONITOR SET) menu
to display the same image as monitor 1)
Control terminal (CONTROL)
•
Alarm input : No voltage, make-contact switch input x 16 (Low input)
•
Sensor alarm output : Alarm output x 16 (low output, normally open (NO))
•
Remote input (R1, R2) : 2-wire type with resistance-based identification system
•
Alarm output (A) : DC 5 V, 5.7 kΩ (Low output)
•
Switching input (S) : Low input, for input signal from SW OUT of timelapse VCR/real time recorder (as
per this manufacturer specifications)
•
RS485 control terminal : RJ-11 type: 2 terminals (A/B), Push-lock type: 3 terminals (A, B, GND)
•
RS-232C terminal : 9-pin D-SUB
Full screen sequence timing : Available in full screen mode, with interval selectable from 1 – 30 sec.
Monitor on-screen display : Title (up to 10 characters), date, time selectable
Menu settings : 10 menus: Language, Clock, VCR, Alarm, Active REC, Monitor, Camera, Position,
Display, Alarm data
Alarm sensor : Internal, 16 channel (each camera input, selectable)
Back-up function : Back-up for up to 30 days of the clock settings after connected for 30 hours
continuously
Operations
•
Still : Available for camera live or VCR playback in full screen and zoomed in picture
Can be set using a menu to operate automatically when there is an alarm trigger
•
2x zoom : Available for camera live or VCR playback in full screen and frozen picture
In full screen mode can switch from frozen to zoomed in picture
Power : AC 120 V, 60 Hz
Consumption : 20 W (MPX-CD162), 18 W (MPX-MD162)
Operating environment : Temperature: 5 to 40˚C, Humidity: 10 to 80%
Dimensions : 420 (W) x 86 (H) x 325 (D) mm
Weight : Approx. 4.1 kg
Products are subject to change in design and specifications without notice and without incurring any obligation.
L8FC5/US (MPX-CD162, MD162 GB) 2000. 8. 31
English 53