Schumacher 00-99-000906/0109 Power Supply User Manual


 
14
Find your battery’s rating on the chart below and note the charge time
given for each charger setting. The times given are for batteries with a 50
percent charge prior to recharging. Add more time for severely discharged
batteries.
BATTERY SIZE/RATING CHARGE RATE/CHARGING TIME
4 AMP 20 AMP 70 AMP
SMALL
BATTERIES
Motorcycle,
graden,
tractor, etc.
6 - 12 AH 1 - 2 hrs NR NR
12 - 32 AH 2 - 5 hrs NR NR
CARS/TRUCKS 200 - 315 CCA 40 - 60 RC 5 ¾ - 7 ¼ hrs 1 ¼ - 1 ½ hrs 20 - 25 min
315 - 550 CCA 60 - 85 RC 7 ¼ - 9¼ hrs 1 ½ - 2 hrs 25 - 30 min
550 - 1000 CCA 80 - 190 RC 9 ¼ - 17 ½ hrs 2 - 3 ½ hrs 30 min - 1 hr
MARINE/DEEP CYCLE 80 RC 8 ¾ hrs 1 ¾ hrs 30 min
140 RC 13 ½ hrs 2 ¾ hrs 45 min
160 RC 15 hrs 3 hrs 1 hr
180 RC 16 ½ hrs 3 ½ hrs 1 ¼ hrs
MAINTENANCE INSTRUCTIONS12.
Before performing maintenance, unplug and disconnect battery charger 12.1
(see sections 6.7 and 7.6).
After use, unplug charger and use a dry cloth to wipe all battery corrosion 12.2
and other dirt or oil from terminals, cords, and the charger case.
After every 100 hours or 12.3
whenever you see dust
accumulating on the fan
blades you should clean
both fans using com-
pressed air (as shown).
NOTE: Use the com-
pressed air on the fan
blades only. Do not blow
dirt into the fan shaft or
bearing.
These fans push a lot of air
and are precision balanced.
Excessive dirt and grime
buildup will cause the fan
to be unbalanced and wear out quickly. If the fans fail, the charger may
overheat and the thermal protection of the charger will shut it down.