• 3 •
Clamp the positive (red) clamp to the positive (POS, P, +) battery post. 4.
Clamp the negative (black) clamp to the negative (NEG, N, -) battery post.
TO TEST THE BATTERY
Once you connect the tester to a battery, the screen will come on and 1.
display BATTERY TEST and the voltage of the battery the tester is
connected to. Press the ENTER button.
The screen will show BATTERY TYPE and STANDARD SLI type of 2.
battery. To change the battery type to VRLA/GEL/AGM/SLA, press the
FORWARD or BACK button. Once the correct battery type has been
selected, press ENTER. (See GLOSSARY for battery denition.)
The screen will show SELECT RATING and either CCA (SAE), IEC, 3.
DIN, JIS or EN battery rating. To change the battery rating, press the
FORWARD or BACK button. Once the correct battery rating has been
selected, press ENTER.
The screen will show SET CAPACITY and a number with the rating you 4.
previously chose. To change the capacity to a different number, press the
FORWARD or BACK button. Once the correct battery capacity has been
selected, press ENTER. The following chart shows the capacity ranges
available for each battery rating.
CCA (SAE): 40 – 2000•
EN: 40 – 2100•
IEC: 30 – 1500•
DIN: 25 – 1300•
JIS: By Battery Type Number•
The screen will show TESTING. After several seconds, the screen will 5.
change to show the results of the test. After the results are displayed,
press ENTER.
NOTE: If the tester determines that the battery voltage is low (based on the
type, rating and capacity that was previously input), it will ask IS BATTERY
CHARGED? This means, has the battery been charged without any drain
placed on it within the last 24 hours. Press the FORWARD or BACK button
to switch between YES and NO. Once the correct option has been selected,
press ENTER.
When the test is complete, the display shows the volts and CCA or 6.
percent of charge. Press the FORWARD or BACK button to select: SOH
(STATE OF HEALTH) or SOC (STATE OF CHARGE). One of ve results
will be displayed:
GOOD AND PASS: The battery is good and capable of holding a charge.•
RECHARGE AND RETEST: The battery is discharged, and the battery •
condition cannot be determined until it is fully charged. Recharge and
retest the battery.
BAD AND REPLACE: The battery will not hold a charge and should be •
replaced.
BAD CELL AND REPLACE: The battery has at least one cell short circuit •
and should be replaced.
LOAD ERROR: The tested battery is bigger than 2000 CCA or 200 Ah, •
or the clamps are not connected properly. Diagnose and correct the
problem, then fully charge the battery and retest it. If the reading is the
same, replace the battery. NOTE: Are there any accessories still turned
on? If yes, turn them off, charge the battery and retest it. If no, replace
the battery since the charging system is working and a good battery
should have accepted a charge.