Seagate SED FIPS140-2 Computer Drive User Manual


 
SEAGATE ENTERPRISE PERFORMANCE 15K HDD AND ENTERPRISE TURBO SSHD SAS PRODUCT MANUAL, REV. B 48
[1] Enterprise Performance 15K HDD and Enterprise Turbo SSHD drives can format to 512, 520, 524, or 528 bytes per logical block.
[2] Warning. Power loss during flash programming can result in firmware corruption. This usually makes the drive inoperable.
[3] Reference Mode Sense command 1Ah for mode pages supported.
[4] Y = Yes. Command is supported.
N = No. Command is not supported.
A = Support is available on special request.
[5] Approximately 1.5 increase in time to complete this command for a SED drive versus a non-SED drive of the same capacity.
Write and Verify (16) 8Eh Y
Write and Verify (32)
7Fh/000Ch N
Write Buffer (modes 0, 2, supported) 3Bh Y (non-SED drives only)
Write Buffer 3Bh
Firmware Download option (modes 5, 7, Ah and Bh) [3] Y (non-SED drives only)
Firmware Download option (modes 4, 5, 7) Y (SED drives only)
Write Long (10) 3Fh Y
Write Long (16) 9Fh/11h Y
Write Same (10) [5] 41h Y
PBdata N
LBdata N
Write Same (16) [5] 93h Y
Write Same (32) 7Fh/000Dh N
XDRead 52h N
XDWrite 50h N
XPWrite 51h N
Table 8 Supported commands
Command name Command code Supported