Seagate ST1000DX001 Laptop User Manual


 
Seagate Desktop SSHD Product Manual, Rev. C 12
www.seagate.com Drive Specifications
2.10 Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All
measurements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power
to operational levels.
2.10.1 Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this
process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-
7) to discern tone audibility and to compensate for the inaudible components of sound prior to computation of
tone ratios according to Annex D of the ECMA-74 standards.
2.11 Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in Table 5.
2.12 Warranty
To determine the warranty for a specific drive, use a web browser to access the following web page:
http://www.seagate.com/support/warranty-and-replacements/
From this page, click on “Check to see if the drive is under Warranty”. Users will be asked to provide the drive
serial number, model number (or part number) and country of purchase. The system will display the warranty
information for the drive.
Note
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the
following equation: (Number of seeks per second = 0.4 / (average latency + average access time
Table 4 Fluid Dynamic Bearing (FDB) motor acoustics
Idle* Seek
4-Disk
(4TB)
2.3 bels (typical)
2.5 bels (max)
2.8 bels (typical)
3.0 bels (max)
2 Disks
(2TB)
2.4 bels (typical)
2.6 bels (max)
2.6 bels (typical)
2.7 bels (max)
1 Disk
(1TB)
2.2 bels (typical)
2.3 bels (max)
2.3 bels (typical)
2.4 bels (max)
Table 5 Radio frequency environments
Test Description
Performance
level
Reference
standard
Electrostatic discharge Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B EN61000-4-2: 95
Radiated RF immunity
80MHz to 1,000MHz, 3 V/m,
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 200Hz
A
EN61000-4-3: 96
ENV50204: 95
Electrical fast transient ± 1 kV on AC mains, ± 0.5 kV on external I/O B EN61000-4-4: 95
Surge immunity ± 1 kV differential, ± 2 kV common, AC mains B EN61000-4-5: 95
Conducted RF immunity 150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz sine A EN61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94