Seagate ST19171N Computer Drive User Manual


 
36 Barracuda 9 Installation Guide, Rev. A
W/WD drives
Other applicable jumper options
Other option jumpers are available as illustrated below.
Figure 13. Additional jumper options
Enable parity check of 
SCSI bus (default).
Disable parity check.
J2
Pin 1
Reserved
Parity Check option
Write protect = Off 
(enables writing – 
default).
Write protect = On 
(disables writing).
Write Protect option
Disable the Delay Motor 
Start option (default).
Motor start delay equal 
to the SCSI ID multiplied 
by 12 seconds. For 
example, if the SCSI 
ID = 2, the drive starts 
in 24 seconds.
Delay Motor Start option 
(valid only if the Enable 
Motor Start jumper is 
not connected)
Enable motor start. The 
drive waits for the Start 
Unit command from the 
host before starting the 
spindle motor.
Disable motor start 
(default). The drive 
starts according to the 
Delay Motor Start option.
Motor Start option
Pin 1
End
SCSI I/O
Connector
Drive with
HDA up, PCB
down, viewed
from front
Pin 1
DC Power
Connector
J2
Drive Front
J6
J1
Pin 1
HDA
J6
A
2
A
1
A
0
Reserved
Remote
LED
L
E
D
R
E
S
R
E
S
Reserved
Shipped with cover installed.
Do not remove.
Do not install jumpers
on these four positions.
J6
Jumper Type
(enlarged to
show detail)
CATH
11
12
J2 Jumper Type
(enlarged to
show detail)