Seagate ST19171WD Computer Monitor User Manual


 
Barracuda 9 Installation Guide, Rev. B 21
SCSI ID jumpers
Each device on the SCSI chain must have a unique SCSI ID.
The host system’s SCSI controller usually uses the highest-num-
bered ID available; therefore the lower-numbered SCSI IDs are
normally used for other SCSI devices such as this Barracuda
disc drive.
Note.
Most SCSI controllers (host adapters) allow you to skip a
SCSI ID. For example, you can have ID0, ID1, and ID3
(skipping ID2). Other controllers do not allow this so be
sure to refer to your system or controller user’s manual
for details about its requirements for proper SCSI device
installation.
Most Barracuda disc drives are factory set with the SCSI ID set
at 0. To change the SCSI ID, refer to the appropriate drive sec-
tion for your model.
If, after completing the installation process, the drive’s LED does
not show on/off activity when the host is trying to communicate
with the drive, a duplicate SCSI ID may be the problem. If this is
the case, change the ID so that each device on the SCSI chain
has its own unique ID. Also check your system or controller
user’s manual to ensure that you have not violated its SCSI ID
numbering recommendations.
Drive termination
If you are installing a Barracuda drive in a system that has other
SCSI devices installed, terminate only the end devices on the
SCSI chain. A SCSI “device” is any disc drive, scanner, tape
backup unit, or other piece of hardware connected to your sys-
tem using the SCSI bus.