Seagate ST33000650NS Laptop User Manual


 
16 CONSTELLATION ES.2 SERIAL ATA PRODUCT MANUAL, REV. H
b. Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification
assumes that the drive is packaged in the shipping container designed by Seagate for use with drive.
HDA Temp.
Check Point
Figure 3. Location of the HDA temperature check point
Note. Image is for reference only, may not represent actual drive
2.9.2 Humidity
2.9.2.1 Relative humidity
Operating: 5% to 90% noncondensing (30% per hour max)
Nonoperating: 5% to 95% noncondensing (30% per hour max)
2.9.3 Altitude
Operating: –60.96 m to 3,048 m (–200 ft. to 10,000+ ft.)
Nonoperating: –60.96 m to 12,192 m (–200 ft. to 40,000+ ft.)
2.9.4 Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting screws. Shock may
be applied in the X, Y or Z axis.
2.9.4.1 Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum operating shock of 70 Gs
(read) and 40 Gs (write) based on half-sine shock pulses of 2ms. Shocks should not be repeated more than two times per second.
2.9.4.2 Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in performance when
subsequently put into operation is 300 Gs based on a nonrepetitive half-sine shock pulse of 2ms duration.
2.9.5 Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the drive mounting screws.
Vibration may be applied in the X, Y or Z axis.