18 CONSTELLATION ES.2 SERIAL ATA PRODUCT MANUAL, REV. H
2.12 ELECTROMAGNETIC IMMUNITY
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected
to the radio frequency (RF) environments defined in the following table:
2.13 RELIABILITY
2.13.1 Annualized Failure Rate (AFR) and Mean Time Between Failures (MTBF)
The product shall achieve an Annualized Failure Rate (AFR) of 0.73% (MTBF of 1.2 million hours) when operated nominal power and
typical case temperatures of 40°C. Operation at temperatures outside the specifications in Section 2.9 may increase the product AFR
(decrease MTBF). AFR and MTBF are population statistics that are not relevant to individual units.
AFR and MTBF specifications are based on the following assumptions for business critical storage system environments:
• 8760 power-on-hours per year.
• Operations at nominal voltages.
• Temperatures outside the specifications in Section 2.9 may reduce thee product reliability.
• Normal I/O duty cycle for enterprise nearline applications. Operation at excessive I/O duty cycle may degrade product reli-
ability.
The enterprise application nearline environment of power-on-hours, temperature, and I/O duty cycle affect the product AFR and MTBF.
2.14 AGENCY CERTIFICATION
2.14.1 Safety certification
These products are certified to meet the requirements of UL60950-1, CSA60950-1 and EN60950 and so marked as to the certify agency.
Table 5 Radio frequency environments
TEST DESCRIPTION
PERFORMANCE
LEVEL
REFERENCE
STANDARD
Electrostatic
discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B EN 61000-4-2: 95
Radiated RF
immunity
80 to 1000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A EN 61000-4-3: 96
ENV 50204: 95
Electrical fast
transient
± 1 kV on AC mains, ± 0.5 kV on external I/O B EN 61000-4-4: 95
Surge immunity ± 1 kV differential, ± 2 kV common, AC mains B EN 61000-4-5: 95
Conducted RF
immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine A EN 61000-4-6: 97
Voltage dips,
interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN 61000-4-11: 94
Nonrecoverable read errors 1 per 10
15
bits read, max
Annualized Failure Rate (AFR) 0.73% (nominal power, 40°C case temperature)
Load unload cycles 300,000 cycles
Warranty To determine the warranty for a specific drive, use a web browser to access the
following web page::
http://www.seagate.com/support/warranty-and-returns
From this page, click on the "Verify Your Warranty" link. You will be asked to provide
the drive serial number, model number (or part number) and country of purchase.The
system will display the warranty information for your drive.
Preventive maintenance None required.