Sharp AR-153E N Copier User Manual


 
34
4
Raise the fusing unit release lever, close the front cover and
then close the side cover by pressing the round projections
near the side cover open button. The misfeed ( ) indicator will
go out and the start ( ) indicator will light up.
5
D: Misfeed in the lower paper feed area (AR-153EN)
1
Open the lower side cover
(under the manual tray) and
remove the misfed paper. If
blinks and the misfed
paper is not seen from the
area of the lower side cover,
pull out the lower paper tray
and remove the misfed
paper. Then close the lower
paper tray.
2
Close the lower side cover.
3
Close the side cover by pressing the round projections near
the side cover open button. The misfeed ( ) indicator will go
out and the start ( ) indicator will light up.
E: Misfeed in the SPF (AR-153EN)
An original misfeed may occur at one of three locations: if the misfed original is seen
from the original feeder tray, (A) in the original feeder tray; if the misfed original is not
seen from the original feeder tray, (B) in the exit area or (C) under the feeding roller.
Remove the misfed original following the instructions for each location.
(A) Open the feeding roller cover and pull the original gently to the left and out
from the original feeder tray. Close the feeding roller cover. Open and close
the original cover to clear the SPF misfeed ( ) indicator. If the misfed
original cannot be easily removed, proceed to (C).
Raise the fusing unit release lever, close the front cover and then close
the side cover by pressing the round projections near the side cover
open button. The misfeed ( ) indicator will go out and the start ( )
indicator will light up.
Feeding roller cover