SIIG UM022_02 Computer Keyboard User Manual


 
4. Addressing
4.1. Addressing of keyboardCUE-S (serial number up to
CS0174.0128) and keyboardCUE-S /w
The ADDRESS of the keyboardCUE-S and keyboardCUE-S /w can be set in the range 0 to 9 by the
firmware. Standard keyboards have address 0, addresses 1 to 9 are delivered on a special order.
The BUTTON_ID transmitted by a panel and BUTTON_LED_ID (tabletop model keyboardCUE-S only)
are numbers used in the programming for button and bargraph identification. Both values depend on a
button position and it depends on a keypad ADDRESS too. Both values are calculated according
formulas
BUTTON_ ID = Offset + Button Code
BUTTON_LED_ID = Offset + Button Code
Offset = 32 * ADDRESS
The lowest BUTTON_ID is generated by a button in the upper left corner the highest BUTTON_ID is
generated by a button in the lower right corner - see example for ADDRESS = 0 on the picture below.
12
34
56
78
12
34
56
78
Button LED Code = 1 Button Code = 1 Button Code = 1
In the table below there is Button ID range for each address.
ADDRESS BUTTON_ID range = BUTTON_LED_ID range
0 1 8
1 33 40
2 65 72
3 97 104
4 129 136
5 161 168
6 193 200
7 225 232
8 257 264
9 289 296
User Manual Small Keyboards
www.cuesystem.com
Page 7 of 18